Non-stock - Business Days to Ship: 15 Days
In Stock

Ultrasound Branching 3-Vein Access Trainer with Artery, Medium Tone

SKU: 500-502-32
500-502-32
Ultrasound Branching 3-Vein Access Trainer with Artery, Medium Tone
Ultrasound Branching 3-Vein Access Trainer with Artery, Medium Tone
Ultrasound Branching 3-Vein Access Trainer with Artery, Medium Tone
Ultrasound Branching 3-Vein Access Trainer with Artery, Medium Tone
Ultrasound Branching 3-Vein Access Trainer with Artery, Medium Tone
Ultrasound Branching 3-Vein Access Trainer with Artery, Medium Tone
Ultrasound Branching 3-Vein Access Trainer with Artery, Medium Tone
Availability:
This product is made to order. The production process begins once the order is received. Expedited shipping methods will only apply once the production process has completed and the items are ready to ship.
Non-stock Item
$590.00
Realistic Training Models Realistic Training Models
50+ Years of Expertise 50+ Years of Expertise
Trusted by Professionals Trusted by Professionals
Custom Solutions Custom Solutions

Frequently Bought Together:

Ultrasound Branching 3-Vein Access Trainer with Artery, Medium Tone
Inc. Tax
Ex. Tax

Description

The Medium Tone Ultrasound Branching 3-Vein Access Trainer with Artery is a tabletop model, made with our Resonance™ ultrasound tissue, is built for a realistic ultrasound-guided training experience. While the vasculature cannot be seen externally, the model contains the same realistic internal features as the clear version, including a 5 mm bifurcated vesse with a 3 mm branch, a 3 mm vein with valve, and a non-collapsing 4 mm artery. This allows learners to practice identifying vessels, differentiating vein from artery, recognizing bifurcations, and locating valves using ultrasound alone.

Ideal for advanced training scenarios, the opaque model helps users develop real-world scanning and access skills without visual cues. Its anatomy supports practice in transverse and longitudinal imaging, vessel compression, needle tip tracking, and catheter placement for IV, PIV, and PICC procedures. When primed with fluid, the model also provides flashback confirmation and supports simulated blood draw. Designed for durability and repeated use, it is only usable with 22 gauge or smaller needles and can provide up to 1,000 sticks with proper handling, flushing, and storage.

Key Features:

  • Opaque design hides anatomy for ultrasound-only training
  • Supports realistic ultrasound-guided vascular access practice
  • Features a 5 mm bifurcated vessel and 3 mm branching vessel
  • Includes a 3 mm vein with valve and non-collapsing 4 mm artery
  • Helps train vessel identification, compression, and landmark recognition
  • Supports transverse and longitudinal scanning
  • Enables flashback confirmation and simulated blood draw
  • For use with 22 gauge or smaller needles only
  • Expected durability of up to 1,000 sticks with proper use
  • Kit includes setup and transport accessories

Kit Includes:

  • Colored tablets for blood solutions
  • 10 cc syringe
  • 50 cc IV bag
  • IV tower for hanging the IV bag
  • Storage/travel bag

Specifications

SKU
500-502-32
Anatomy
Arm
Model Type
Vascular Access
Material
Ultrasound
Overall Dimensions
11 x 5 x 10

Warranty

Care, Handling, Usage, and Storage Guidelines for Resonance™ Material

Resonance™ material is designed for durability and repeated training use when handled, used, stored, and maintained according to recommended guidelines. To help preserve product performance and maintain warranty coverage, follow the care, handling, usage, and storage instructions below.

Care and Handling

Handle Resonance™ material with care during setup, training, cleaning, and storage. Avoid placing unnecessary stress, weight, or pressure on the material, as this may deform or damage the product. Do not leave the material in contact with paper or other surfaces that may transfer ink, dye, or residue.

After use, clean the material according to the product’s recommended care instructions. Resonance™ material must be stored clean and dry when not in use.

Usage Guidelines

Use Resonance™ material only as intended and according to the instructions provided for the specific product. When needle access is required, use only the recommended needle sizes listed in each product’s description. Use of non-approved needle sizes may damage the material and reduce product performance.

Where lubrication is recommended, apply the appropriate lubrication before use. Using the material without recommended lubrication may result in unnecessary wear or damage.

Do not leave needles, devices, or other instruments in place for extended periods unless specifically instructed, as prolonged contact may affect material performance or cause damage.

Storage Guidelines

Store Resonance™ material clean and dry when not in use. Do not store the material while wet, soiled, compressed, or under any weight. Proper storage helps maintain the shape, function, and longevity of the product.

Avoid storage conditions that may expose the material to unnecessary pressure, contamination, moisture, direct sunlight, or contact with materials that could stain or damage the surface.

Warranty Coverage

Damage resulting from use, storage, or care outside of these recommendations is not covered under warranty. This includes, but is not limited to, use with non-approved needle sizes, leaving the material in contact with paper, storing the material under any weight, storing the material while wet or soiled, leaving devices in place for extended periods, or using the material without recommended lubrication where applicable.

Failure to follow care, handling, storage, and usage instructions may reduce product performance and void warranty coverage.